Indo Powersys Pvt. Ltd.

High Frequency True Online UPS

In today’s digitally dependent world, even a split-second power failure can cause data loss, hardware damage, and business disruption. Whether you are running a data center, a corporate server room, or a sensitive industrial control system, a reliable True Online UPS is critical. Indo Powersys Pvt. Ltd., a trusted name in Indian power solutions, introduces […]

In today’s digitally dependent world, even a split-second power failure can cause data loss, hardware damage, and business disruption. Whether you are running a data center, a corporate server room, or a sensitive industrial control system, a reliable True Online UPS is critical. Indo Powersys Pvt. Ltd., a trusted name in Indian power solutions, introduces the IP Series – a high-frequency, double-conversion True Online UPS designed for critical applications ranging from 1KVA to 3KVA.
Let’s explore how this intelligent UPS series delivers uninterrupted, clean, and efficient power to safeguard your business-critical operations.

Key Features of Indo Powersys IP Series UPS (1KVA–3KVA)

This IP Series UPS system is designed using advanced DSP-controlled double conversion technology, ensuring 100% isolation between input and output, regardless of fluctuations or outages in the mains power supply. Here are its most notable features:

  • True Double Conversion Online Technology: Ensures constant voltage and frequency regulation by converting incoming AC to DC and back to AC, offering pure power output regardless of input anomalies.
  • High-Frequency IGBT Technology: Incorporates IGBT (Insulated Gate Bipolar Transistor) in both inverter and rectifier stages, enhancing switching performance and reducing power loss.
  • Fully Digital Microprocessor Control: Advanced DSP (Digital Signal Processor) architecture ensures high-speed monitoring and instant corrective responses.
  • Wide Input Voltage Range: Operates efficiently within 110–300VAC, adapting automatically to input fluctuations without switching to battery, thus extending battery life.
  • High Input Power Factor (0.99): Minimizes energy losses and enhances power quality by drawing sinusoidal input current, making it energy efficient and utility-friendly.
  • Up to 91% Efficiency: One of the most energy-efficient systems in its class, reducing electricity bills and heat output.
  • Advanced Battery Management: Includes features like cold start, charging in UPS OFF mode, and fast recovery from deep discharge. Supports both inbuilt and long-run battery configurations.
  • Comprehensive LCD Display: Real-time display of input/output voltage, frequency, load percentage, battery status, operation mode, and fault notifications.
  • Smart Communication Options: Equipped with RS232 and optional SNMP for remote monitoring, real-time alerts, and graceful auto shutdown of connected systems.
  • Compliant with Global Standards: Fulfills major international certifications like ISO 9001, 14001, 27001, and conforms to IEC/EN 62040 & CE/RoHS directives.

Applications

The IP Series UPS from Indo Powersys is purpose-built for mission-critical and high-sensitivity environments:

  • Data Centers & Server Rooms
  • Telecom Base Stations
  • IT and Networking Equipment
  • Banking & ATM Enclosures
  • Industrial Control Panels
  • CCTV and Security Systems
  • Medical Labs & Diagnostic Equipment

Technical Specifications Overview

Model IP110L3 IP1102L6 IP1103L6 IP1103L8 (Long Run)
Capacity (VA) 1000 2000 3000 3000
Output Power Factor 0.8 0.8 0.8 0.8
Input Voltage Range 110–300VAC (load-based)
Frequency Range 45–55Hz (50Hz); 54–66Hz (60Hz)
Input Power Factor >0.99
Output Voltage 220/230/240VAC ±2%
Waveform True Sine Wave
Crest Factor 03:01
Efficiency >91%
Transfer Time 0 ms (AC to Battery), 4 ms (AC to Bypass)
Battery Voltage 36V 72V 96V 96V
Battery Configuration 3, 6, or 8 x 12V/7Ah SMF VRLA
Recharge Time 8 hours (to 90%)
Charge Current (Std./Long Run) 1A / 6A
Noise Level <45dB
Altitude <1500m
Communication RS232, SNMP (optional), Dry Contacts
Protection Overload, Short Circuit, Overcharge, Overheat
Standards IEC/EN 62040, IS 16242:2014, RoHS

Display & Indicator Functions

  • LCD Display: Shows real-time data on voltage, frequency, battery levels, load %, temperature, and faults.
  • LED Indicators:
    • Green: Normal Operation
    • Amber: Battery Mode
    • Yellow: Warning
    • Red: Fault Condition

Physical & Environmental Specs

Model Standard Unit (kg) Long Run Unit (kg) Dimension (WxDxH)
IP110L3 14 / 16 144 x 421 x 215 mm
IP1103L8 34 / 36 191 x 478 x 339 mm
  • Operating Temp: 0°C – 40°C
  • Storage Temp: -25°C – 55°C
  • Humidity: 0–95% RH (Non-condensing)

Benefits at a Glance

  • No Transfer Delay – Ensures continuous operation during power loss.
  • Smart Charging – Keeps batteries healthy and ready for next outage.
  • Advanced Safety – Inbuilt surge, overload, and short circuit protection.
  • Eco-Friendly – RoHS compliant and energy efficient.
  • Customizable Runtime – Add external batteries for extended backup.

Frequently Asked Questions (FAQ)

Q1: What is a True Online UPS and how is it different from Line Interactive UPS?
A: A True Online UPS uses double-conversion to provide isolated, stable, and pure power regardless of input conditions. Unlike Line Interactive UPS, it has zero transfer time, ideal for sensitive and critical equipment.

Q2: Can I use the IP Series UPS with my server setup?
A: Absolutely. It is specifically designed for servers, networking gear, and industrial applications where uninterrupted and clean power is essential.

Q3: How long does the battery last during a power cut?
A: It offers 8–16 minutes backup at 50% load using inbuilt batteries. However, the IP1103B8 model supports external batteries for longer backup, even up to several hours.

Q4: Is SNMP monitoring supported?
A: Yes. The UPS comes with RS232 communication by default and an optional SNMP slot for real-time remote monitoring and alerts.

Q5: How does the system respond to overload or short circuit?
A: It automatically shifts to bypass mode:

  • 110% Load: Bypass in 30 seconds
  • 150% Load: Bypass in 300ms
  • This prevents hardware damage and ensures system safety.

Q6: Can I monitor the UPS parameters without a PC?
A: Yes. The LCD panel provides real-time visibility of all operational parameters, battery condition, and fault status.

Q7: What type of batteries are used?
A: The UPS uses Sealed Maintenance-Free (SMF), VRLA batteries, which are safe, compact, and don’t require any user maintenance.

Q8: How often should I replace the batteries?
A: Typically, batteries last 2–3 years, depending on usage and ambient temperature. Regular maintenance checks are recommended.

Q9: Is the UPS compatible with generators?
A: Yes. The wide input voltage/frequency range allows it to work seamlessly with generator power, making it perfect for extended power outages.

Q10: Where can I buy or get technical support?
A: Contact Indo Powersys at:

  • J-1249, Phase III, Sitapura Industrial Area, Jaipur-22
  • 0141-2771421 / 2771422
  • info@ips2k.com | indopowersys@gmail.com
  • ips2k.com
Leave a Reply